Product Description

15KW 3 phase charging power module AC/DC converter 50-

500V for battery charger 40A

 

SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.

Functional details

1. Hot plug

Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.

2. Advanced current sharing technology

Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than ±0.5A.

3. Control of input limited power

Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 15KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.

4. Control of output constant power

When there is a rated input voltage, the output power of the module is 15KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.

The SD50040G module uses two operating modes with output voltage ranges of 50 to 500V.

The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.

5. Temperature limited power

6. Regulation of output current limiting point

8. Regulation of output voltage

The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 500Vdc and minimum regulation step of 0.1 Vdc.

9. Fan control

The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.

10. Protection of input overvoltage/ voltage shortage

11. Output overvoltage protection

The overvoltage protection point is 260Vdc ~550Vdc (±10 Vdc). Default is 550Vdc.The module can be started after manual intervention upon overvoltage protection.

12. Over-temperature protection

The environmental over-temperature protection point is 80°C. When the DC panel has a temperature over 100°C, the module will stop working; when the DC panel has a temperature below 90°C, the module will automatically work again.

13. Protection of internal bus fault

When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.

14. Short circuit protection

In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".

Category

Name

Parameter

Environmental conditions

Operation temperature

-40°C ~ +75°C, derating is require when the temperature is above 55°C.

Storage temperature

-40°C ~ +70°C

Relative humidity

≤95%RH, without condensation

Cooling mode

Forced air cooling

Altitude

2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l.

Atmospheric pressure

79 kPa ~ 106 kPa

AC input

Input system

Three phases + PE

Rated voltage

380 Vac

Rated frequency

50Hz/60Hz

DC output

Rated voltage

375Vdc (voltage range 50-500V)

Rated current

40A

Over voltage

500V

Steady voltage precision

<±0.5%

Steady current precision

≤±1% (rated range of 20% ~ 100% for output load)

Load regulation rate

≤±0.5%

Grid regulation rate

≤±0.1% (testing range is 432V ~ 530V)

Startup overshoot

≤±3%

Peak-to-peak value noise

≤1% (150~750V, 0~20MHz)

Power factor and THD

Power factor

≥0.95   Full-load output power of @20%~50%

≥0.98   Full-load output power of @50%~100%

≥0.99  Full-load output power, input nominal voltage and frequency of @100%

THD

≤5%  Full-load output power of  @50%~100%

Efficiency

Under Rated input voltage

95.2%,@500V50%~100

 

 

EMC

Emission

ClassA , Meet the requiremnt of  NB/T 33001-1-2010,NB/T 33008-1-2013  

Immunity

C lassA , Meet the requiremnt of  NB/T 33001-1-2010,NB/T 33008-1-2013  

Current sharing

In case of load of 10%~100%, the module current sharing error ≤ rated output current of ±5%.

Noise

65dB(1m away

Startup duration (select the startup mode through the monitoring module)

Normal startup mode: the time delay from AC power-on to module output is ≤ 8s.

Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s.

Earthing resistance

Earthing resistance ≤ 0.1Ω, bearable current ≥ 25A

Surge protection

Meets IEEE C62 41-1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave)

Insulation  resistance

The insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ.

Insulation strength

AC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA;

AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady-state leakage current is less than

1mA;

DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA;

Price Terms︰ FOB Shanghai

Payment Terms︰ TT

Lead Time︰ 8 days

Standards Certificate︰ CE, ISO9001