7kw single phase high frequency switching power supply 50-750VDC battery charge

 7kw single phase high frequency switching power supply 50-750VDC battery charge

Model No.︰SD75020S

Brand Name︰SANDI

Country of Origin︰China

Unit Price︰US $ 2100 / pc

Minimum Order︰1 pc

Inquire Now

Product Description

7kw high frequency switching power supply modular with 50-750VDC rectifier battery charger

 

High Frequency Switching Power Supply/Rectifier Module/Battery Charger/AC to DC Module for Eletrical Power/Substation DC Power Supply

SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.

Functional details

1.    Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2.    Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than ±0.5A.
3.    Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4.   Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
Note:
The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V.  Boot without a demand voltage.The default operation is in the low-voltage segment mode; if the monitored demand voltage is higher than 600V, the module will automatically switch to the high-voltage segment mode. When the demand voltage is lower than 550V At the same time, it automatically cuts back to the low pressure section mode.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.
5.    Temperature limited power
Under 55°C ambient temperature, the module can output full power of 20kW;
Over 55°C ambient temperature, the module shall be used by derating with the power Linearly .
Under 65°C ambient temperature, the allowable output power of the module is 10kW.
Under 75°C ambient temperature, the output power of the module is reduced to 0.
6.    Regulation of output current limiting point
The module has the function of stepless current limiting. The current limiting point within the scope of 0~33.3A(High voltage)/0A~50A(low voltage) is adjustable through the external monitoring module. When the output voltage is within 50Vdc ~ 750Vdc, the current limiting accuracy of the module is ±0.3A.
8.    Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9.    Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10.  Protection of input overvoltage/ voltage shortage
When the input voltage is less than 260 Vac or more than 530 Vac, the protection indicator light is on and the module stops working, without output.
when the module is in Single-phase communication mode, the input voltage is less than 160 Vac or more than 300 Vac, the protection indicator light is on and the module stops working, without output Meanwhile, this condition will be transmitted to the monitoring module. The function can be recovered automatically.
11.  Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc (±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
12.  Over-temperature protection
The environmental over-temperature protection point is 80°C. When the DC panel has a temperature over 100°C, the module will stop working; when the DC panel has a temperature below 90°C, the module will automatically work again.
13.  Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14.  Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
15.  Interruption of background communication

Product Parameters

Category

Name

Parameter

Environmental conditions

Operating temperature

-40°C ~ +75°C, derating is required when the temperature is above 55°C.

Storage temperature

-40 ~ +70

Relative humidity

≤95%RH, No condensation

Cooling way

Forced air cooling

Altitude

2000m, derating is required when the altitude is above 2000 m

Atmospheric pressure

79kPa ~ 106kPa

AC input

Input phase

Single phase L/N or L1/L2 + PE

Voltage range

180-260Vac

Rated voltage

220Vac

Maximum current

<32A

Grid frequency

45Hz~65Hz

Rated frequency

50Hz/60Hz

DC output

Output power

7KW @ voltage >350Vdc

Voltage range

150-750Vdc

Current range

0 ~ 20A

Steady voltage precision

<±0.5%

Steady current precision

≤±1%(rated range of 20% ~ 100% for output load)

Load regulation rate

≤±0.5%

Grid regulation rate

≤±0.1% (testing range is 320V ~ 530V)

Startup overshoot

≤±3%

Power factor and THD

Power factor

0.95  Full-load output power of @20%~50%

0.98  Full-load output power of @50%~100%

0.99  Full-load output power, input nominal voltage and frequency of @100%

THD

5%  Full-load output power of @50%~100%

Noise index

Peak-to-peak value noise

1% (150~750V, 0~20MHz)

Others

Safety requirements

Class A , Meet the requirement of NB/T 33001-1-2010,NB/T 33008-1-2013  

Efficiency

94.5%, @750V, 50%~100% load current, under rated input voltage

Instant impulse current upon startup

<20A

Temperature Coefficient(1/)

≤±0.01%

Startup duration (select the startup mode through the monitoring module)

Normal startup mode: the time delay from AC power-on to module output is 8s.

Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s.

Noise

65dB(A) (1m away)

Earthing resistance

Earthing resistance 0.1Ω, bearable current 25A

Leakage current

Leakage current3.5mA

Surge protection

Meets IEEE C62 41-1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave)

Insulation resistor

The insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be 10MΩ.

Insulation strength

AC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA;

AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady-state leakage current is less than

1mA;

DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA;

ROHS

R5

Mechanical parameters

Size

87Mm (H) ×177.5mm (W) ×385mm (D)

Weight

15kg

Price Terms︰ FOB Ningbo

Payment Terms︰ TT

Lead Time︰ 10 days

Standards Certificate︰ CE, ISO9001

Product Image